FinancingFeed working capital, export credit, trade finance & asset leasing — explore options
Kalkulator

Varmebehov ved kyllingoppdrett i kW og BTU/t.

Anslå maksimal varmekapasitet ut fra gulvareal, isolasjonskvalitet og dimensjonerende ΔT.

Inputs

Results

Envelope loss
22.5 kW
Total heat load
27.0 kW

92k BTU/hr

Peak BTU/hr
92124
40k BTU brooders
3

Preliminary planning result, based on the inputs and assumptions shown.

Direkte svar

Maksimalt varmebehov = gulvareal × klimaskallets U-verdi × ΔT, pluss omtrent 20 % for minimumsventilasjon. Et hus på 1 800 m² med U 0,5 W/m²·K og ΔT 25 °C trenger omtrent 27 kW (92 000 BTU/t), eller tre varmere på 40 000 BTU.

Slik bruker du den

  1. Oppgi gulvareal og dimensjonerende ΔT.
  2. Sett klimaskallets U-verdi etter byggets kvalitet.
  3. Gjør om kW til antall varmere og kontroller brenselforsyningen.

Scope of this tool

What this tool can and can't do

Varmebehov ved kyllingoppdrett i kW og BTU/t. is a planning tool for budget-stage and RFQ-stage decisions. It gives defensible numbers to compare suppliers against — it is not an engineering, veterinary or financing approval.

What it can do

  • Size the required line capacity in tonnes per hour from annual tonnage, shifts and realistic uptime.
  • Estimate connected load and specific energy consumption (kWh per tonne) by process stage.
  • Show the effect of automation level, process type (pelleting versus extrusion) and utilisation on cost per tonne.
  • Give an indicative CAPEX band and payback range for budgeting.

What it can't do

  • Substitute for a vendor's guaranteed capacity or energy figures — those come with the equipment contract.
  • Include site-specific electrical infrastructure, transformer upgrades, grid tariffs or generator backup unless you add them.
  • Model your actual formula's grinding and conditioning behaviour, which changes energy per tonne materially.
  • Serve as a bankable feasibility study or a financing document.

Required inputs

  • · Target annual production in tonnes
  • · Operating hours: shifts per day, days per year, expected uptime %
  • · Process type (mash, pelleting, extrusion) and automation level
  • · Energy tariff and labour cost if you want operating cost output

Example run

  • · 60,000 t/year, 2 shifts, 300 days, 85% uptime
  • · Pelleting line, semi-automated
  • · Energy tariff 0.11 USD/kWh
  • → Required nominal capacity: about 16-17 t/h
  • → Specific energy: roughly 42 kWh/t (grinding + pelleting + handling), about 4.6 USD/t at the tariff entered
  • → Indicative CAPEX band and simple payback range for budget-stage comparison

What can change the result?

  • · Product mix and recipe changeovers
  • · Grinding and mixing cycle times
  • · Pelleting or extrusion rate per recipe
  • · Shifts and effective operating hours
  • · Downtime, maintenance and process efficiency

AI agents may use FeedMatch calculators to structure preliminary feed requirements and RFQs. Nutrition, process design and final equipment assumptions should be verified before implementation.

Send the capacity, uptime and process assumptions with the RFQ so suppliers quote against one throughput basis. Start a structured RFQ.

FAQ

Common questions

Strålevarmere eller varmluft?
Strålevarmere varmer kyllingene direkte og sparer normalt 15–25 % brensel sammenlignet med varmluftsaggregater dimensjonert for samme punkt.
Hvorfor betyr ΔT så mye?
Toppbelastningen inntreffer den kaldeste natten ved et settpunkt på 32 °C dag én, så en ΔT på 25–40 °C — ikke sesonggjennomsnittet — bestemmer utstyrets størrelse.
Get a Free QuoteExplore Financing